HDPE Water Supply Pipe Winbel
Urban area water -supply work system. Large diameter HDPE pipe is healthy and non-toxic and more suitable for urban water supply main conduit and buried tube.
Applications
1. Urban water supply system. Large diameter HDPE pipe is healthy and non-toxic, which is more suitable for urban water supply mains and buried pipes.
2. Replace cement tube, iron pipe and steel tube. Applicable for renovation project and does not need large area excavation, HDPE pipe can be widely used in old town of pipe network reconstruction.
3. Pipeline for conveying industrial materials. Chemical industry, chemical fiber, food, forestry, pharmaceutical, light industry, paper making, metallurgy and other industrial raw materials transportation pipeline.
4. Landscaping water supply network. As landscaping project needs lots of water supply pipes, HDPE pipe is the best choice for this toughness and low costs.
5. Sewage discharge pipes.HDPE pipe have unique corrosion resistance, can be used as industrial wastewater and sewage discharged pipe.
6. Ore and mud transfers. HDPE pipe has high resistance to stress and wear resistance, can be widely applied in conveying ore, coal ash and river bait-casting mud. HDPE Agricultural irrigation pipe Winbel
7. Agricultural irrigation pipe. HDPE pipe has the merits of great flow and good impact resistance, it is the ideal tool for agricultural irrigation.
High quality raw material is the core of the product.
Our products are manufactured by excellent materials lke BOREALIS, BASELL, TOTAL, DAELIM, SABIC, etc., which ensure the quality satisfying your demand.
https://www.winbelpipe.com/hdpe-water-supply-pipe/hdpe-water-supply-pipe.html
Properties
Characteristics
|
Requirements
|
Specific Gravity, g/cm3,(20℃)
|
0.941-0.965
|
Longitudinal Reversion, %, (110℃)
|
≤3
|
Oxidation Induction Time, min, (200 ℃)
|
≥20
|
Extension Rate at Break, %
Melt Mass Flow Rate, g/10min(195℃,5KG)
Hydrostatic Strength
1) 20℃,Hoop Stress: PE100 12.4 Mpa, PE80 9.0Mpa, 100h
2) 80℃,Hoop Stress: PE100 5.4Mpa, PE80 4.5Mpa, 165h
3) 80℃,Hoop Stress: PE100 5.0Mpa, PE80, 4.0Mpa, 1000h
|
≥350
Change of MFR by processing ±20%
No Failure
No Failure
No Failure
|